CEV750DVL50
The CEV-DVL50 Series voltage sensors are designed for accurate measurement of DC, AC, pulsed, and arbitrary voltage signals while ensuring galvanic isolation between the primary and secondary circuits. These sensors provide high accuracy, low power consumption, and superior interference immunity, making them ideal for demanding industrial and power applications

Product Overview
Low power consumption for energy-efficient operation. Compact and robust design, ensuring easy integration into various systems. High accuracy and low drift, providing stable and precise measurements. Fast response time, enabling real-time monitoring of voltage fluctuations. Superior immunity to external electromagnetic interference, enhancing performance in harsh environments. Reliable dielectric insulation, ensuring safety and long-term
Key Features
- Low power consumption for energy-efficient operation.
- Compact and robust design, ensuring easy integration into various systems.
- High accuracy and low drift, providing stable and precise measurements.
- Fast response time, enabling real-time monitoring of voltage fluctuations.
- Superior immunity to external electromagnetic interference, enhancing performance in harsh environments.
- Reliable dielectric insulation, ensuring safety and long-term
Technical Specifications
| Parameter | Value |
|---|---|
| Supply Voltage (VC) | ±12V to ±24V (±5%) |
| Current Consumption (IC) | 20 mA |
| Bandwidth | 14 kHz |
| Output Current (IOUT) | 50 mA |
| Accuracy @ VPN, TA = 25°C | ±0.7% |
| Rated Input Voltage (VPN) | 750 V |
| Maximum Input Voltage (VPM) | -750 V to 750 V |
| Offset Current (IO) | +/- 0.2 mA |
| Operating Temperature | from -40 °C to 85 °C |
Compliance & Standards
- EN 50155: 2021
- ● EN 50178: 1997
- ● EN 50124-1: 2017
- ● EN 50121-3-2: 2016
- ● UL 508: 2013.
- CE Tested
- ROHS Tested
Quick Reference
- Part Number
- CEV750DVL50
- Type
- Voltage Sensor
Applications
- Power Supplies
- Drives
- Traction