Product Series
CEC300CLT100
Closed-loop (compensated) current measurement

Product Overview
Closed-loop (compensated) current measurement Galvanic isolation between primary and secondary Through-hole design for busbar mounting High accuracy and excellent linearity Fast response time (<1 μs) Wide frequency bandwidth (up to 150 kHz) Low temperature drift High immunity to external interference Easy installation and robust mechanical design
Key Features
- Closed-loop (compensated) current measurement
- Galvanic isolation between primary and secondary
- Through-hole design for busbar mounting
- High accuracy and excellent linearity
- Fast response time (<1 μs)
- Wide frequency bandwidth (up to 150 kHz)
- Low temperature drift
- High immunity to external interference
- Easy installation and robust mechanical design
Technical Specifications
| Parameter | Value |
|---|---|
| Supply Voltage (VC) | ±15 to ±24 V |
| Current Consumption (IC) | < 30 + IS mA |
| Bandwidth | DC – 150 kHz |
| Rated Input Current (IPN) | 300 A |
| Measuring Range (IPM) | ±900 A |
| Accuracy @ IPN, TA = 25°C | < ±0.5 % |
| Offset Current (IO) | < ±0.2 mA |
Compliance & Standards
- CE Tested,
- ROHS Tested
Quick Reference
- Part Number
- CEC300CLT100
- Type
- Current Sensor