CE_ DHAB5S2L

CEV50DVL50, CEV125DVL50, CEV150DVL50, CEV250DVL50, CEV500DVL50, CEV750DVL50, CEV1000DVL50, CEV1500DVL50, CEV2000DVL50 P/N: CEV_DVL50 Series
The CEV-DVL50 Series voltage sensors are designed for accurate measurement of DC, AC, pulsed, and arbitrary voltage signals while ensuring galvanic isolaƟon between the primary and secondary circuits. These sensors provide high accuracy, low power consumpƟon, and superior interference immunity, making them ideal for demanding industrial and power applicaƟons.

Key Features:

  • Low power consumption
  • Compact & rugged design
  • High measurement accuracy with low drift
  • Fast response time for real-time monitoring
  • High immunity to electromagnetic interference
  • Reliable dielectric insulation

Applications:

  • Single-phase & three-phase inverters
  • Braking choppers
  • Substation monitoring
  • High-power drive units
  • Industrial power conversion systems

Performance:

  • Accuracy: ±0.7%
  • Sensitivity Error: ±0.5%
  • Linearity Error: 0.5%
  • Response Time: 30 µs
  • Bandwidth: 14 kHz
  • Following Accuracy: 100 A/µs

Installation:

  • Primary Connection: 2 × M5 threaded post
  • Secondary Connection: 3 × M5 threaded post or 6.3 × 0.8 mm terminal
  • Ensure proper wiring to avoid sensor damage
  • Custom configurations available upon request

Electrical Specifications (TA = 25°C, Vcc = ±24V)

Parameter

Range / Values

Nominal Primary Voltage

50V to 2000V (model dependent)

Measuring Range

Up to ±3000V

Sensitivity

16.67 µA/V to 1000 µA/V

Supply Voltage

±12V to ±24V (±5%)

Quiescent Current

20 mA

Output Current (Nominal/Max)

50 mA / 75 m

Measuring Resistance

0–47Ω (@±12V), 0–200Ω (@±24V)

Power Consumption0.2W

0.2W